MV/LV Containerised Transformers (2000kVA – 8000kVA, 400-34.6kV)
- MV and LV switchgears installed
- Dry and oil transformers
- Equipped with overcurrent and short-circuit protection
- Installed in ISO containers
- Available variants of ONAN or ONAF
- High temerautra working up to 50 ° C
- Stackable
- 4 field insulators for flexible wiring
ATS - Automatic Transfer Switch
- 19 "rack modules/stand
- 400V
- 3x230V
- Max Current 32AMP
- 50 Hz frequency
- Change-over operation time - <50ms
- 5U height
- Width 19 "
Mobile power distribution board 250AMP - 9x32A 400v
- 9x 32A 400V CEE sockets
- 250 AMP
- electrical power meter
- 5x POWERLOCK 400AMP
Mobile power distribution board 400AMP - 15x32A 400v
- 15x 32A 400V CEE sockets
- 400 AMP
- electrical power meter
- 5x POWERLOCK 400AMP
Temporary cold and hot aisle containment
- Very quick and simple assembly
- Near-perfect representation of the target corridors
- Perfect for testing precision air conditioning systems
- Possibility of adapting the structure at every stage of building a data hall
Wireless temperature & humidity sensors
- Ability to monitor parameters from 150 sensors
- Create alerts
- Live view of parameters
- measuring resolution: 0.1 °C
- operating range: - 40 to 125°C
- Live view of parameters
- Simple implementation
MV Resisitive/Reactive Containerised Loadbanks (2000kVA – 8000kVA, 400-34.6kV)
- Voltage from 600v to 33kV
- 50 – 60 HZ
- Resistive & Resistive-Reactive
- 20, 30 & 40 ft container sizes
- 1000kVA to 6000kVA
- IP55 standard protection
- Multiple 1kVA/1kW load steps
- Stainless steel finned elements
- Choice of control system for all units – suited to application & operators
- Ambient temperature operation to 45°C
USB - data logger
- Measurement range -30-80 ° C
- Measurement range: 0-100% RH
- Recording capacity: 32256 records
- Simple implementation
Power quality analyzer SONEL PQM 707
- Inrush current.
- Inverter efficiency.
- Crest factors for current CFI and voltage CFU.
- Frequency within the range of 40...70 Hz.
- Active (P), reactive (Q), distortion (D) and apparent (S) power with the type of reactive power (capacitive and inductive).
- Active (EP), reactive (EQ) and apparent (ES) energy.
Sonel Multifunction Insulation, Loop, RCD, Ground Resistance & Power Tester
- Measurement of fault loop impedance ZL-PE, ZL-N, ZL-L
- Measurement of fault loop impedance ZL-PE RCD mode
- Measurement of earth resistance RE by 3p and 4p
- Selective measurement of earth resistance clamp (3p + clamp)
- Selective measurement of ground with two clamps
- Measurement of soil resistivity (ρ)
- Indicate the phase sequence