Rack Mounted load bank Rack-22/400 (22x1kW) low delta T
RACK-22/400 devices provide the most advanced solution for server simulation and HVAC temperature testing in data center rooms and other dedicated installations.

Main advantages:
- 19 "rack modules/stand
- 22kW load
- Simple operation
- Working mode: Auto/Manual
- Low delta T
- Height of 13HU
- Load steps 22x1kW
Time saving in carrying out tests and in controlling load banks thanks to the connected version and its associated supervision software Our 19-inch rack-mount load banks are specifically designed to meet the requirements of data center “IST commissioning” testing. With their low Delta T, they reduce computer room overheating, thereby overloading air conditioning systems. In addition, their low heat generation prevents damage to heat-sensitive peripherals (lighting fibers, cables, fire detection systems, etc.)
Delta T range from 454 to 908 CMH - Adjustable delta T in the range of 12°C -20°C
For prices, enquiries or bespoke options, call our rental team on +48 516 182 866 or email office@loadbanks.pl or use our templates Offer inquiry or Contact form .
| Type Ref | Rack-22/400 |
| Max Voltage | 400 volts, three phase 50/60 hz |
| Full Load Rating | Nominal: 22kW (22 x 1000W, 31,75A 400V), (±5%) |
| Controls | MANUAL: 22 separate 1000W loads at 400V each load adjustable in 22 steps of 1000W from panel AUTO: 22 separate 1000W loads at 400V each load adjustable in 22 steps of 1000W from the computer |
| Adjustment | 22 x 1000W steps selected via panel or computer by LBX software |
| Connection | 1 x CEE 32A 5P on the front of the device |
| Cooling | 1 fan with horizontal air circulation, powered from a loaded source. Drawing cool air from the forehead, heat discharge to the rear |
| Airflow | 4300m3/h |
| Element Type | The resistors mounted on the mica composite card. |
| Construction | Loadbank: Aluminum / Steel, powder coated front panel. Closed, with ventilation grille at the back. |
| Operating Temperature | 0-55°C |
| Storage Temperature | 0-50°C |
| Movement | Handles on the front panel, wheels |
Additional solutions for data center tests:
- LBX- Loadbanks management system - Our proprietary management software for load banks
- Wireless temperature & humidity senors - temperature sensors for live monitoring of temperature and air humidity during tests in Data Center.
- Thermal camera - to analyse the various hot spots
- Analysers - to analyse electrical network
- Temporary cold and hot aisle containment -perfect for testing precision air conditioning systems
- Power distribution board - temporary distribution board when dedicated power supply for Data center is not available
- ATS - Automatic Transfer Switch - Allows to switch the electrical load between track A and track B
Delivery and Installation options:
- Our standard services include: preparation of transport equipment and services, delivery
- In addition, we can provide: local vision of the test site and preparation of assembly drawings, installations, disassembly, connection, load tests performed by qualified employees
Any questions call our rental team on +48 516 182 866 or email office@loadbanks.pl