Rack Mounted load bank Rack-20/400 (2x10kW) for Data Center
The Rack-20/400 model is designed to perform safe load tests of the entire DataCenter system together with power generators, UPS devices and ventilation and air conditioning (HVAC) installations.
Main advantages:
- 19 "rack modules
- 20kW load
- Simple operation
- Backcable connections
- Additional collateral
- Low cost
- Height of 12HU
- Load steps 2x10kW
A full test using a load bank is essential for business continuity planning and should be completed before any assumption of risk. This is a very important aspect of overall risk management as most power failures are as a result of human error, poor maintenance or planning, rather than war, terrorism or natural disasters. Initially there should be a witness test of the performance of the standby system following its installation and commissioning or any major upgrade.
The Rack-20/400 device provides a cheap 19 "solution for server simulation and HVAC temperature testing in Data Centers rooms and other dedicated installations. Load is another proprietary Loadbanks product. The device due to the use of an efficient fan provides twice as much air flow as a standard building heater.
For prices, enquiries or bespoke options, call our rental team on +48 516 182 866 or email office@loadbanks.pl or use our templates Offer inquiry or Contact form .
Type Ref | Rack-20/400 |
Max Voltage | 400 volts, three phase 50/60 hz |
Full Load Rating | Nominal: 20kW (2 x 10000W, 28,8A 230V), (±5%) |
Controls | 2 separate loads with a power of 10,000 W and a voltage of 400V. Each load is adjustable in 1 step of 10,000W |
Adjustment | 2 x 10000W, set from the front panel |
Connection | 1 x 32A 5P on the back of the device |
Cooling | 1 fan with horizontal air circulation, powered from a loaded source. Drawing cool air from the forehead, heat discharge to the rear |
Airflow | 1 x 2800 m3 / h real, 4000m3 / h nominal |
Element Type | The resistors mounted on the mica composite card. |
Construction | Loadbank: Aluminum / Steel, powder coated front panel. Closed, with ventilation grille at the back. |
Operating Temperature | 0-55°C |
Storage Temperature | 0-50°C |
Movement | Handles on the front plate |
Delivery and Installation options:
- Our standard services include: preparation of transport equipment and services, delivery
- In addition, we can provide: local vision of the test site and preparation of assembly drawings, installations, disassembly, connection, load tests performed by qualified employees
Any questions call our rental team on +48 516 182 866 or email office@loadbanks.pl